Item Added to Cart
 
 
 
Log In / Sign Up
Forgot Password?
New User Sign Up
Quick Order
Item # Unit Qty









Featured Brands
DWK Kimble logo J.T.Baker Macron Logo Hamilton Logo
View All Brands

Meters, Dissolved Oxygen Meter, Lab Star Benchtop Meter, Orion™

 

You have not viewed any products recently.

 
Orion Lab Star DO Dissolved Oxygen Bench Meters
View Larger
Orion Lab Star DO Dissolved Oxygen Bench Meters
  • LabStarDO Dissolved Oxygen Bench Meter
  • Orion Lab Star DO Dissolved Oxygen Bench Meters
 
  • alt view name
  • alt view name

Meters, Dissolved Oxygen Meter, Lab Star Benchtop Meter, Orion™

Lab Star DO113 Dissolved Oxygen Bench Meters
Measure dissolved oxygen as percent saturation or concentration in ppm or mg/L with temperature using the Orion Lab Star DO113 DO bench meter. Featuring a large, backlit display for easy viewability and small footprint to save bench space, this DO meter is ideal for simplified, budget-friendly testing. Use the onscreen stabilizing and ready indicators to help identify when DO meter readings are complete. View active calibration logs with date and time stamp, record key measurements using the 500-point data log with date and time stamp, and output all logs to a printer or computer.
  • G133-12 is the DO meter and stand option, which allows you to purchase your DO electrode separately
  • G133-13 is the standard DO meter kit option, for a wide variety of dissolved oxygen samples including BOD with the included adapter
GSA
 
  • Budget-friendly DO meter for simplified dissolved oxygen as percent saturation or concentration testing
  • Display shows dissolved oxygen, barometric pressure, temperature and salinity simultaneously for accurate data recording
  • Measure 0.0 to 300.0 % saturation, 0.00 to 30.0 mg/L or ppm and -5.0 to 105.0°C or 23.0 to 221.0°F to ensure comprehensive measurement capabilities
  • Perform 100% and 0% saturation calibrations, one point concentration calibration using a custom value (Winkler) and one point temperature adjustment calibrations for proficient SOP compliance
  • Use automatic barometric pressure compensation for DO measurements with manual value entry in mmHg or bar
  • Use automatic salinity compensation for DO measurements with value manual entry of 0.0 to 50.0 ppt
  • Large 5 inch backlit display makes viewing and recording measurements easy
  • Small meter footprint saves valuable bench space in your lab
  • Onscreen stabilizing and ready indicators help identify when readings are complete
  • Date and time data stamped data and calibration logs support GLP compliance
  • View active DO and temperature calibration logs with date and time stamp to ensure accurate, reproducible measurements
  • Use 500-point data log with date and time stamp to record key measurements
  • Output data and calibration logs to a printer or computer for long-term data storage
  Lab Star Dissolved Oxygen Bench Meters
Measurement Modes Dissolved oxygen as percent saturation with temperature; dissolved oxygen as concentration in mg/L with temperature; dissolved oxygen as concentration in ppm with temperature
Sensor Types Polarographic
Range (Polarographic DO) 0.0 to 300.0% saturation; 0.00 to 30.0mg/L or ppm
Resolution (Polarographic DO) 0.1, 1% saturation; 0.01, 0.1mg/L or ppm
Accuracy (Polarographic DO) ±2% saturation ±1 LSD; ±0.2mg/L ±1 LSD
Pressure Range 400.0 to 850.0mm Hg; 0.533 to 1.133 bar
Calibration Modes 100% saturation, 0% saturation, custom concentration value
Temperature Range -5.0°C to +105.0°C
Resolution (Temperature) 0.1°C, 0.1°F
Accuracy (Temperature) ±0.3°C, ±0.5°F
Temperature Selection Manual or automatic with ATC temperature probe
Temperature Probe Calibration 1 point temperature offset calibration
Display Type 5 inch backlit LCD
Backlight Option Yes
Memory Non-volatile
Data Points 500 data sets with time and date
Log Function Type Automatic with Auto-Read & Timed read modes, manual with Continuous read mode
Data Management Details Continuous, Auto-Read and Timed read modes
Alarm Output Calibration reminder alarm
Inputs 9-pin MiniDIN for DO with built-in ATC
Outputs Computer or printer (STARA-106)
Certifications/Compliance CE, TUV 3-1, FCC Class A
IP Rating IP54
AC Adapter Universal 100-240V 50/60Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets
Dimensions (L x W x H) 187.2 x 155.2 x 61.7mm, 7.37 x 6.11 x 2.43 inch
Weight 700 grams, 1.54 lbs
Relative Humidity Range 5 to 85%, non-condensing
Warranty 3 year meter warranty
Percent Saturation Range Polarographic DO 0.0 to 300.0% saturation
GSA Link

Ordering Info

Cat No Vendor Part No ModelIncludes Qty Price Qty UOM
G133-12 LSTAR1130 Dissolved Oxygen Bench Meter with StandMeter, Electrode stand, PC cable, Universal power adapter In Stock 1 $908.00 EA
G133-13 LSTAR1135 Dissolved Oxygen Bench Meter with Standard KitMeter, Electrode stand, PC cable, Universal power adapter; 083005MD polarographic DO/ATC probe with calibration sleeve; G135-45 DO probe maintenance kit; G125-25 BOD adapter In Stock 1 $1,430.00 EA

Options

Cat No Vendor Part No Description Qty/UOM Price Qty UOM
C750-3 LSTAR-ARM Orion Lab Star series Electrode Stand with meter-attachable bracket In Stock 1 $105.00 EA
C750-4 LSTAR-PWR Orion Lab Star series 100-240V / 50/60Hz Universal Power Adapter with twist-and-lock connector In Stock 1 $52.30 EA
C750-5 LSTAR-USB Orion Lab Star series USB Computer Cable In Stock 1 $52.30 EA
C750-6 LSTAR-CVR Orion Lab Star series Meter Dust Cover In Stock 1 $52.30 EA
 

Enter full name. We'll ask for delivery information at checkout.